Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Science ; 375(6582): 782-787, 2022 02 18.
Article in English | MEDLINE | ID: covidwho-1650668

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Beta variant of concern (VOC) resists neutralization by major classes of antibodies from COVID-19 patients and vaccinated individuals. In this study, serum of Beta-infected patients revealed reduced cross-neutralization of wild-type virus. From these patients, we isolated Beta-specific and cross-reactive receptor-binding domain (RBD) antibodies. The Beta-specificity results from recruitment of VOC-specific clonotypes and accommodation of mutations present in Beta and Omicron into a major antibody class that is normally sensitive to these mutations. The Beta-elicited cross-reactive antibodies share genetic and structural features with wild type-elicited antibodies, including a public VH1-58 clonotype that targets the RBD ridge. These findings advance our understanding of the antibody response to SARS-CoV-2 shaped by antigenic drift, with implications for design of next-generation vaccines and therapeutics.


Subject(s)
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19/immunology , Cross Reactions , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Adolescent , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/chemistry , Antibodies, Neutralizing/genetics , Antibodies, Viral/genetics , Antibodies, Viral/metabolism , Antigenic Drift and Shift , COVID-19/virology , Female , Humans , Male , Middle Aged , Neutralization Tests , Protein Binding , Protein Domains , Protein Interaction Domains and Motifs , SARS-CoV-2/chemistry , SARS-CoV-2/genetics , Spike Glycoprotein, Coronavirus/chemistry , Spike Glycoprotein, Coronavirus/genetics , Spike Glycoprotein, Coronavirus/metabolism
2.
Lancet Respir Med ; 9(11): 1255-1265, 2021 11.
Article in English | MEDLINE | ID: covidwho-1594095

ABSTRACT

BACKGROUND: Heterologous vaccine regimens have been widely discussed as a way to mitigate intermittent supply shortages and to improve immunogenicity and safety of COVID-19 vaccines. We aimed to assess the reactogenicity and immunogenicity of heterologous immunisations with ChAdOx1 nCov-19 (AstraZeneca, Cambridge, UK) and BNT162b2 (Pfizer-BioNtech, Mainz, Germany) compared with homologous BNT162b2 and ChAdOx1 nCov-19 immunisation. METHODS: This is an interim analysis of a prospective observational cohort study enrolling health-care workers in Berlin (Germany) who received either homologous ChAdOx1 nCov-19 or heterologous ChAdOx1 nCov-19-BNT162b2 vaccination with a 10-12-week vaccine interval or homologous BNT162b2 vaccination with a 3-week vaccine interval. We assessed reactogenicity after the first and second vaccination by use of electronic questionnaires on days 1, 3, 5, and 7. Immunogenicity was measured by the presence of SARS-CoV-2-specific antibodies (full spike-IgG, S1-IgG, and RBD-IgG), by an RBD-ACE2 binding inhibition assay (surrogate SARS-CoV-2 virus neutralisation test), a pseudovirus neutralisation assay against two variants of concerns (alpha [B.1.1.7] and beta [B.1.351]), and anti-S1-IgG avidity. T-cell reactivity was measured by IFN-γ release assay. FINDINGS: Between Dec 27, 2020, and June 14, 2021, 380 participants were enrolled in the study, with 174 receiving homologous BNT162b2 vaccination, 38 receiving homologous ChAdOx1 nCov-19 vaccination, and 104 receiving ChAdOx1 nCov-19-BNT162b2 vaccination. Systemic symptoms were reported by 103 (65%, 95% CI 57·1-71·8) of 159 recipients of homologous BNT162b2, 14 (39%, 24·8-55·1) of 36 recipients of homologous ChAdOx1 nCov-19, and 51 (49%, 39·6-58·5) of 104 recipients of ChAdOx1 nCov-19-BNT162b2 after the booster immunisation. Median anti-RBD IgG levels 3 weeks after boost immunisation were 5·4 signal to cutoff ratio (S/co; IQR 4·8-5·9) in recipients of homologous BNT162b2, 4·9 S/co (4·3-5·6) in recipients of homologous ChAdOx1 nCov-19, and 5·6 S/co (5·1-6·1) in recipients of ChAdOx1 nCov-19- BNT162b2. Geometric mean of 50% inhibitory dose against alpha and beta variants were highest in recipients of ChAdOx1 nCov-19-BNT162b2 (956·6, 95% CI 835·6-1095, against alpha and 417·1, 349·3-498·2, against beta) compared with those in recipients of homologous ChAdOx1 nCov-19 (212·5, 131·2-344·4, against alpha and 48·5, 28·4-82·8, against beta; both p<0·0001) or homologous BNT162b2 (369·2, 310·7-438·6, against alpha and 72·4, 60·5-86·5, against beta; both p<0·0001). SARS-CoV-2 S1 T-cell reactivity 3 weeks after boost immunisation was highest in recipients of ChAdOx1 nCov-19-BNT162b2 (median IFN-γ concentration 4762 mIU/mL, IQR 2723-8403) compared with that in recipients of homologous ChAdOx1 nCov-19 (1061 mIU/mL, 599-2274, p<0·0001) and homologous BNT162b2 (2026 mIU/mL, 1459-4621, p=0·0008) vaccination. INTERPRETATION: The heterologous ChAdOx1 nCov-19-BNT162b2 immunisation with 10-12-week interval, recommended in Germany, is well tolerated and improves immunogenicity compared with homologous ChAdOx1 nCov-19 vaccination with 10-12-week interval and BNT162b2 vaccination with 3-week interval. Heterologous prime-boost immunisation strategies for COVID-19 might be generally applicable. FUNDING: Forschungsnetzwerk der Universitätsmedizin zu COVID-19, the German Ministry of Education and Research, Zalando SE.


Subject(s)
BNT162 Vaccine/immunology , COVID-19 , ChAdOx1 nCoV-19/immunology , Immunogenicity, Vaccine , Antibodies, Viral/blood , COVID-19/prevention & control , Germany , Health Personnel , Humans , Immunoglobulin G/blood , Neutralization Tests , Prospective Studies , SARS-CoV-2 , Vaccination
3.
Nature ; 602(7896): 307-313, 2022 02.
Article in English | MEDLINE | ID: covidwho-1585832

ABSTRACT

Emerging variants of concern (VOCs) are driving the COVID-19 pandemic1,2. Experimental assessments of replication and transmission of major VOCs and progenitors are needed to understand the mechanisms of replication and transmission of VOCs3. Here we show that the spike protein (S) from Alpha (also known as B.1.1.7) and Beta (B.1.351) VOCs had a greater affinity towards the human angiotensin-converting enzyme 2 (ACE2) receptor than that of the progenitor variant S(D614G) in vitro. Progenitor variant virus expressing S(D614G) (wt-S614G) and the Alpha variant showed similar replication kinetics in human nasal airway epithelial cultures, whereas the Beta variant was outcompeted by both. In vivo, competition experiments showed a clear fitness advantage of Alpha over wt-S614G in ferrets and two mouse models-the substitutions in S were major drivers of the fitness advantage. In hamsters, which support high viral replication levels, Alpha and wt-S614G showed similar fitness. By contrast, Beta was outcompeted by Alpha and wt-S614G in hamsters and in mice expressing human ACE2. Our study highlights the importance of using multiple models to characterize fitness of VOCs and demonstrates that Alpha is adapted for replication in the upper respiratory tract and shows enhanced transmission in vivo in restrictive models, whereas Beta does not overcome Alpha or wt-S614G in naive animals.


Subject(s)
COVID-19/transmission , COVID-19/virology , Mutation , SARS-CoV-2/classification , SARS-CoV-2/physiology , Virus Replication , Amino Acid Substitution , Angiotensin-Converting Enzyme 2/genetics , Angiotensin-Converting Enzyme 2/metabolism , Animals , Animals, Laboratory/virology , COVID-19/veterinary , Cricetinae , Disease Models, Animal , Epithelial Cells/virology , Female , Ferrets/virology , Humans , Male , Mesocricetus/virology , Mice , Mice, Transgenic , SARS-CoV-2/genetics , SARS-CoV-2/growth & development , Spike Glycoprotein, Coronavirus/genetics , Spike Glycoprotein, Coronavirus/metabolism , Virulence/genetics
4.
Transbound Emerg Dis ; 69(2): 221-226, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1546411

ABSTRACT

West Nile Virus (WNV) infections are increasingly detected in birds and horses in central Europe, with the first mosquito-borne autochthonous human infection detected in Germany in 2019. Human infections are typically asymptomatic, with occasional severe neurological disease. Because of a low number of cases in central Europe, awareness regarding potential cases is low and WNV diagnostic testing is not routine. We tested cerebrospinal fluid (CSF) samples from unsolved encephalitis and meningitis cases from Berlin from 2019 to 2020, and describe a WNV-encephalitis case in a 33-year-old kidney transplant recipient. The infectious course was resolved by serology, RT-PCR and sequencing of stored samples. Phylogenetic sequence analysis revealed a close relationship of the patient's WNV strain to German sequences from 2019 and 2020. A lack of travel history and patient self-isolation during the SARS-CoV-2 pandemic suggest the infection was acquired in the patient's home or garden. Serological tests of four people sharing the living space were negative. Retrospective RT-PCR and WNV-IgM testing of 671 CSF samples from unsolved encephalitis and meningitis cases from Berlin detected no additional infections. The recent increase of WNV cases illustrates the importance of considering WNV in cases of meningoencephalitis, especially in immunocompromised patients, as described here. Proper education and communication and a revised diagnostic strategy will help to raise awareness and to detect future WNV infections.


Subject(s)
Kidney Transplantation , West Nile Fever , West Nile virus , Adult , Humans , West Nile Fever/diagnosis
5.
Science ; 373(6551)2021 07 09.
Article in English | MEDLINE | ID: covidwho-1243685

ABSTRACT

Two elementary parameters for quantifying viral infection and shedding are viral load and whether samples yield a replicating virus isolate in cell culture. We examined 25,381 cases of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in Germany, including 6110 from test centers attended by presymptomatic, asymptomatic, and mildly symptomatic (PAMS) subjects, 9519 who were hospitalized, and 1533 B.1.1.7 lineage infections. The viral load of the youngest subjects was lower than that of the older subjects by 0.5 (or fewer) log10 units, and they displayed an estimated ~78% of the peak cell culture replication probability; in part this was due to smaller swab sizes and unlikely to be clinically relevant. Viral loads above 109 copies per swab were found in 8% of subjects, one-third of whom were PAMS, with a mean age of 37.6 years. We estimate 4.3 days from onset of shedding to peak viral load (108.1 RNA copies per swab) and peak cell culture isolation probability (0.75). B.1.1.7 subjects had mean log10 viral load 1.05 higher than that of non-B.1.1.7 subjects, and the estimated cell culture replication probability of B.1.1.7 subjects was higher by a factor of 2.6.


Subject(s)
Asymptomatic Infections , COVID-19/transmission , COVID-19/virology , SARS-CoV-2/physiology , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , COVID-19/diagnosis , COVID-19 Nucleic Acid Testing , Caco-2 Cells , Child , Child, Preschool , Female , Germany , Hospitalization , Humans , Infant , Male , Middle Aged , Probability , SARS-CoV-2/isolation & purification , SARS-CoV-2/pathogenicity , Viral Load , Virus Replication , Virus Shedding , Young Adult
6.
Nat Commun ; 12(1): 2117, 2021 04 09.
Article in English | MEDLINE | ID: covidwho-1174671

ABSTRACT

To estimate the seroprevalence and temporal course of SARS-CoV-2 neutralizing antibodies, we embedded a multi-tiered seroprevalence survey within an ongoing community-based cohort study in Bonn, Germany. We first assessed anti-SARS-CoV-2 immunoglobulin G levels with an immunoassay, followed by confirmatory testing of borderline and positive test results with a recombinant spike-based immunofluorescence assay and a plaque reduction neutralization test (PRNT). Those with a borderline or positive immunoassay result were retested after 4 to 5 months. At baseline, 4771 persons participated (88% response rate). Between April 24th and June 30th, 2020, seroprevalence was 0.97% (95% CI: 0.72-1.30) by immunoassay and 0.36% (95% CI: 0.21-0.61) when considering only those with two additional positive confirmatory tests. Importantly, about 20% of PRNT+ individuals lost their neutralizing antibodies within five months. Here, we show that neutralizing antibodies are detectable in only one third of those with a positive immunoassay result, and wane relatively quickly.


Subject(s)
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19/diagnosis , Immunoglobulin G/immunology , SARS-CoV-2/immunology , Adult , Aged , Aged, 80 and over , COVID-19/prevention & control , COVID-19/virology , Cohort Studies , Female , Germany , Humans , Immunoassay/methods , Male , Middle Aged , Neutralization Tests/methods , Population Surveillance/methods , SARS-CoV-2/physiology , Seroepidemiologic Studies
7.
Lancet Microbe ; 2(7): e311-e319, 2021 07.
Article in English | MEDLINE | ID: covidwho-1171807

ABSTRACT

BACKGROUND: Antigen point-of-care tests (AgPOCTs) can accelerate SARS-CoV-2 testing. As some AgPOCTs have become available, interest is growing in their utility and performance. Here we aimed to compare the analytical sensitivity and specificity of seven commercially available AgPOCT devices. METHODS: In a single-centre, laboratory evaluation study, we compared AgPOCT products from seven suppliers: the Abbott Panbio COVID-19 Ag Rapid Test, the RapiGEN BIOCREDIT COVID-19 Ag, the Healgen Coronavirus Ag Rapid Test Cassette (Swab), the Coris BioConcept COVID-19 Ag Respi-Strip, the R-Biopharm RIDA QUICK SARS-CoV-2 Antigen, the nal von minden NADAL COVID-19 Ag Test, and the Roche-SD Biosensor SARS-CoV Rapid Antigen Test. Tests were evaluated on recombinant SARS-CoV-2 nucleoprotein, cultured endemic and emerging coronaviruses, stored respiratory samples with known SARS-CoV-2 viral loads, stored samples from patients with respiratory pathogens other than SARS-CoV-2, and self-sampled swabs from healthy volunteers. We estimated analytical sensitivity in terms of approximate viral concentrations (quantified by real-time RT-PCR) that yielded positive AgPOCT results, and specificity in terms of propensity to generate false-positive results. FINDINGS: In 138 clinical samples with quantified SARS-CoV-2 viral load, the 95% limit of detection (concentration at which 95% of test results were positive) in six of seven AgPOCT products ranged between 2·07 × 106 and 2·86 × 107 copies per swab, with an outlier (RapiGEN) at 1·57 × 1010 copies per swab. The assays showed no cross-reactivity towards cell culture or tissue culture supernatants containing any of the four endemic human coronaviruses (HCoV­229E, HCoV­NL63, HCoV­OC43, or HCoV­HKU1) or MERS-CoV, with the exception of the Healgen assay in one repeat test on HCoV-HKU1 supernatant. SARS-CoV was cross-detected by all assays. Cumulative specificities among stored clinical samples with non-SARS-CoV-2 infections (n=100) and self-samples from healthy volunteers (n=35; cumulative sample n=135) ranged between 98·5% (95% CI 94·2-99·7) and 100·0% (97·2-100·0) in five products, with two outliers at 94·8% (89·2-97·7; R-Biopharm) and 88·9% (82·1-93·4; Healgen). False-positive results did not appear to be associated with any specific respiratory pathogen. INTERPRETATION: The sensitivity range of most AgPOCTs overlaps with SARS-CoV-2 viral loads typically observed in the first week of symptoms, which marks the infectious period in most patients. The AgPOCTs with limit of detections that approximate virus concentrations at which patients are infectious might enable shortcuts in decision making in various areas of health care and public health. FUNDING: EU's Horizon 2020 research and innovation programme, German Ministry of Research, German Federal Ministry for Economic Affairs and Energy, German Ministry of Health, and Bill & Melinda Gates Foundation.


Subject(s)
COVID-19 , SARS-CoV-2 , Antigens, Viral/analysis , COVID-19/diagnosis , COVID-19 Testing , Humans , Point-of-Care Systems , SARS-CoV-2/genetics
8.
Euro Surveill ; 25(3)2020 01.
Article in English | MEDLINE | ID: covidwho-1004613

ABSTRACT

BACKGROUND: The ongoing outbreak of the recently emerged novel coronavirus (2019-nCoV) poses a challenge for public health laboratories as virus isolates are unavailable while there is growing evidence that the outbreak is more widespread than initially thought, and international spread through travellers does already occur. AIM: We aimed to develop and deploy robust diagnostic methodology for use in public health laboratory settings without having virus material available. METHODS: Here we present a validated diagnostic workflow for 2019-nCoV, its design relying on close genetic relatedness of 2019-nCoV with SARS coronavirus, making use of synthetic nucleic acid technology. RESULTS: The workflow reliably detects 2019-nCoV, and further discriminates 2019-nCoV from SARS-CoV. Through coordination between academic and public laboratories, we confirmed assay exclusivity based on 297 original clinical specimens containing a full spectrum of human respiratory viruses. Control material is made available through European Virus Archive - Global (EVAg), a European Union infrastructure project. CONCLUSION: The present study demonstrates the enormous response capacity achieved through coordination of academic and public laboratories in national and European research networks.


Subject(s)
Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Coronavirus Infections/virology , Coronavirus/classification , Coronavirus/genetics , COVID-19 Testing , COVID-19 Vaccines , Clinical Laboratory Techniques/methods , Coronavirus/isolation & purification , Disease Outbreaks , Humans , RNA, Viral/analysis , Real-Time Polymerase Chain Reaction/methods , Sensitivity and Specificity
9.
Cell ; 183(4): 1058-1069.e19, 2020 11 12.
Article in English | MEDLINE | ID: covidwho-785287

ABSTRACT

The emergence of SARS-CoV-2 led to pandemic spread of coronavirus disease 2019 (COVID-19), manifesting with respiratory symptoms and multi-organ dysfunction. Detailed characterization of virus-neutralizing antibodies and target epitopes is needed to understand COVID-19 pathophysiology and guide immunization strategies. Among 598 human monoclonal antibodies (mAbs) from 10 COVID-19 patients, we identified 40 strongly neutralizing mAbs. The most potent mAb, CV07-209, neutralized authentic SARS-CoV-2 with an IC50 value of 3.1 ng/mL. Crystal structures of two mAbs in complex with the SARS-CoV-2 receptor-binding domain at 2.55 and 2.70 Å revealed a direct block of ACE2 attachment. Interestingly, some of the near-germline SARS-CoV-2-neutralizing mAbs reacted with mammalian self-antigens. Prophylactic and therapeutic application of CV07-209 protected hamsters from SARS-CoV-2 infection, weight loss, and lung pathology. Our results show that non-self-reactive virus-neutralizing mAbs elicited during SARS-CoV-2 infection are a promising therapeutic strategy.


Subject(s)
Antibodies, Monoclonal/immunology , Antibodies, Viral/immunology , Betacoronavirus/metabolism , Coronavirus Infections/pathology , Pneumonia, Viral/pathology , Angiotensin-Converting Enzyme 2 , Animals , Antibodies, Monoclonal/therapeutic use , Antibodies, Neutralizing/immunology , Antibodies, Viral/therapeutic use , Antigen-Antibody Reactions , Betacoronavirus/immunology , Betacoronavirus/pathogenicity , Binding Sites , COVID-19 , Coronavirus Infections/drug therapy , Coronavirus Infections/virology , Cricetinae , Crystallography, X-Ray , Disease Models, Animal , Humans , Kinetics , Lung/immunology , Lung/metabolism , Lung/pathology , Mice , Mice, Inbred C57BL , Molecular Dynamics Simulation , Pandemics , Peptidyl-Dipeptidase A/chemistry , Peptidyl-Dipeptidase A/metabolism , Pneumonia, Viral/drug therapy , Pneumonia, Viral/virology , Protein Binding , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/chemistry , Spike Glycoprotein, Coronavirus/immunology , Spike Glycoprotein, Coronavirus/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL